Cleanrooms depend on precisely controlled environmental conditions. To minimize contamination risks and protect people and assets, their technological infrastructure must adhere to the most stringent quality standards. We draw on decades of experience to tailor our integrated cleanroom solutions to your facility’s specific requirements, ensuring all environmental parameters are controlled, monitored and securely stored accordingly.
Facing issue in account approval? email us at info@ipt.pw
Click to Ckeck Our - FREE SEO TOOLS
ICLEAN produces a wide range of Cleanroom compatible doors, meant for air ingression in the room. The door is fitted with mechanically-interlocked vertical edges that add strength and rigidity, making them perfectly suitable for light and heavy use.
Cleanroom doors are available with an interfacing profile for a flush and easy installation on the existing walls.
Fully flush surfaces with wall system
A large variety of swing out pharmaceutical doors
Manual, semiautomatic and fully-automatic sliding doors
Door hardware by leading global manufacturers
Custom dimensions
Cleanroom doors are available with an interfacing profile for a flush and easy installation on the existing walls.
Fully flush surfaces with wall system
A large variety of swing out pharmaceutical doors
Manual, semiautomatic and fully-automatic sliding doors
Door hardware by leading global manufacturers
Custom dimensions
ICLEAN GRP PANELS
Proved Design standards of cGMP
Modular Wall and walkable non progressive ceiling panel
Integrated RAR and windows
100% resistant to Hydrogen Peroxide
Life span will be >35 years
Colour pigments are mixed with Resin, NO need to paint
WALL AND CEILING PANEL SYSTEM
Standard main wall panels or low-level extract panels are 958mm wide and are linked together with 234 wide infill / service panels, allowing the optimum gap for a silicone joint.
Proved Design standards of cGMP
Modular Wall and walkable non progressive ceiling panel
Integrated RAR and windows
100% resistant to Hydrogen Peroxide
Life span will be >35 years
Colour pigments are mixed with Resin, NO need to paint
WALL AND CEILING PANEL SYSTEM
Standard main wall panels or low-level extract panels are 958mm wide and are linked together with 234 wide infill / service panels, allowing the optimum gap for a silicone joint.
Demountable & Relocatable clean room wall partitions consisting of sandwich type (double skin) flushed panels with High Pressure laminate (HPL) 4mm thick with Different infill options ,Material with GI/Alu Profile for reinforcement on Periphery , with suitable height Floor Track arrangement to accommodate Epoxy / PVC coving flush with Panel with Inbuilt raiser & Electrical sockets provision available including silicon sealant & all Necessary accessories.
MOBILE LAMINAR AIR FLOW UNIT / STRERILE TROLLEY
Cleanroom trolley is useful for transporting sterile products under ISO Class 5 (Class 100) particle free work area, which is continuously supplied with positive pressure HEPA filtered circulated horizontal air flow.
Two stage filtration- EU6 and EU 14
Statically & dynamically balanced Motor-blower
Battery back-up with inverter for 30 mins
PU coated Lockable castor wheels
SS 304 removable Shelves
Differential Pressure Gauge
Cleanroom trolley is useful for transporting sterile products under ISO Class 5 (Class 100) particle free work area, which is continuously supplied with positive pressure HEPA filtered circulated horizontal air flow.
Two stage filtration- EU6 and EU 14
Statically & dynamically balanced Motor-blower
Battery back-up with inverter for 30 mins
PU coated Lockable castor wheels
SS 304 removable Shelves
Differential Pressure Gauge
BIO-SAFETY CABINETS
Class II cabinets are designed for work or activities involving microorganisms assigned to biosafety levels 1, 2 and 3.
Bio-safety gives Cleanroom personnel the required environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet. Additionally, the downward laminar flow of HEPA-filtered air provides product protection by minimizing the chance of cross-contamination along the work surface of the cabinet.
Class II cabinets are designed for work or activities involving microorganisms assigned to biosafety levels 1, 2 and 3.
Bio-safety gives Cleanroom personnel the required environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet. Additionally, the downward laminar flow of HEPA-filtered air provides product protection by minimizing the chance of cross-contamination along the work surface of the cabinet.
Cleanrooms depend on precisely controlled environmental conditions. To minimize contamination risks and protect people and assets, their technological infrastructure must adhere to the most stringent quality standards. We draw on decades of experience to tailor our integrated cleanroom solutions to your facility’s specific requirements, ensuring all environmental parameters are controlled, monitored and securely stored accordingly.
MODULAR LAB TABLE
ISLAND WORKTABLE IS USED FOR PERFORMING VARIOUS TESTS BY SCIENTIST/CHEMISTS.
Our Work Tables are manufactured in various designs and shapes, custom made to suit customer's requirements. The construction material is epoxy coated galvanized iron with suitable thickness. The system are designed to be fitted with pedestal system and as per clients specifications. Provision for reagent racks, valves for water and gas along with required electrical connections and any other provisions as required. The system is designed and available with various knee gap models or continous mod
ISLAND WORKTABLE IS USED FOR PERFORMING VARIOUS TESTS BY SCIENTIST/CHEMISTS.
Our Work Tables are manufactured in various designs and shapes, custom made to suit customer's requirements. The construction material is epoxy coated galvanized iron with suitable thickness. The system are designed to be fitted with pedestal system and as per clients specifications. Provision for reagent racks, valves for water and gas along with required electrical connections and any other provisions as required. The system is designed and available with various knee gap models or continous mod
ICLEAN offers Cleanroom equipment within the Cleanroom for Biotech Pharmaceuticals, Microelectronics, Laboratory, Semi conductor units and Hospitals. We provide tailor made solution and design cleanroom equipments for specific use. The equipments are designed with durability, ease of use, compactness and aesthetics in focus. Our design engineers have incorporated many small features that differentiates our products.
The unit is required for the deactivating contaminants from the Personnel protective equipment’s for the persons working in the Potent area’s in Formulation R&D Lab.
The Mist shower should ensure that each and every part of the PPE is exposed to the mist thereby ensuring that the contaminants are adhered to the garment so that they are not easily released in the environment.
Mist shower also prevents risk of spreading even in the areas outside the shower cabinet.
The Mist shower should ensure that each and every part of the PPE is exposed to the mist thereby ensuring that the contaminants are adhered to the garment so that they are not easily released in the environment.
Mist shower also prevents risk of spreading even in the areas outside the shower cabinet.
A Fume Hood is a type of local ventilation device that limits exposure to hazardous or noxious fumes, vapors or dust. ICLEAN offers a big lineup of benchtop, walk-in, and teaching hoods, including a wide selection of hood accessories, cabinets, countertops and blowers. Our Fume Hoods cut exposure to hazardous chemicals and agents used in the laboratory.
Cleanrooms depend on precisely controlled environmental conditions. To minimize contamination risks and protect people and assets, their technological infrastructure must adhere to the most stringent quality standards. We draw on decades of experience to tailor our integrated cleanroom solutions to your facility’s specific requirements, ensuring all environmental parameters are controlled, monitored and securely stored accordingly.